BELIMO Globe Valves
Globe Valves
H2..X-S, 2-way, with internal thread
H3..X-S, 3-way, with internal thread
H6..W-SP, 2-way, with flange PN16
H7..W-S, 3-way, with flange PN16
H7..W-D, 3-way, with flange PN16
Last Update : 15:42:02 18/11/2015
H6..X..-S(P)2 Globe valve, 2-way, Flange, PN 25
Globe valve, 2-way, Flange, PN 25
? For closed (high temperature) hot water and steam systems in the non-critical range
? For water-side modulating control of air-handling and heating systems
Brand : REGIN
Model : RCF-230D
RCF-230D
Room thermostat for fan-coil applications
with on/off outputs.
Intended to control heating and/or cooling in 2- or 4-pipe
installations. Setpoint and fan speed are set using the buttons on the front.
Brand : REGIN
Model : RCF-230AD
RCF-230AD is a room controller intended to control
heating and/or cooling in 2- or 4-pipe installations.
Setpoint and fan speed are set using the buttons on the
front.
Brand : REGIN
Model : RC-DO Room controller with display
RC-DO
Room controller with display
? Awarded design
? Simple installation
? On/Off or 0...10 V control
RC-DO is a room controller from the Regio Mini series
intended to control heating and cooling in a zone control
system.
Brand : BELIMO
Model : D6200W ,D6250W, D6300W
Butterfly valve with Wafer types
? For open and closed cold and warm water systems
? For switching heat generators or cooling machines on and off
Thermal Energy Meter
Superstatic 440 (Cast-iron version)
Thermal energy meter
Superstatic 440+Supercal 531+Temperature sensor
Design
The energy meter consists of a Superstatic 440 flow sensor, a Supercal 531 (AC 24V) integrator and a pair of temperature sensors. Consumption values can be read easily on display.
Temperature sensor pair
Supercal 531 integrators in combination with Superstatic flow sensors are supplied as standard in Pt500 version. The temperature sensors are matched to one another. They are always supplied in pairs and must not be separated, extended or shortened. In the case of a temperature sensor paired with a cable longer than 3m, we recommend the exclusive use of screened temperature sensor pairs. In this case, the screening must be fitted correctly.
Measurement technique
The Supercal 531 with AC 24V power supply records the supply and the return temperature every 3 seconds. The recording flow rate is dependent on the pulse value of the flow sensor unit and is constantly updated. From the mean flow rate, the temperature difference and the heat coefficient will calculate the energy of the captured medium and display on the 8-digit LCD.
Functional description
The top level of Superstatic flow sensors is always the sensor level with feedback loops. The sensor frequency/pulses are directly proportional to the flow/volume. The oscillating jet level has an acceleration section with interactive action. The oscillate frequency of the oscillating jet and the electrical signals generated do not need any external energy source. The water inlet and outlet have a fluid input optimised for flow and an integrated straight section, which makes an external straight section up to DN40 redundantly.